8.8.3.2 Set the time delay
The delay can be set between 0 and 600 seconds. The delay is counted down from 600 in 1
second increments with the «DOWN» key and counted upwards from 0 (zero) in 1 second
increments with the «UP» key.
1. Use «Up» or «Down» to select the
td line.
2. Press «Enter».
The
td delay time flashes.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.10.3.1 p1
Menu
active:
☐
······························
SP:
0.40bar ¦ SD:
−0.2bar
Switching point (SP) and switching differential (SD)
td
120s ¦ Logic
+
Delay (td) and logic
DOR1.01
☐
Output DOR
DOT1.01
☐
Output DOT
3. Use «Up» or «Down» to set the time delay in seconds.
4. Press «Enter».
Result The
td delay time has been set.
8.8.3.3 Assign and activate the output
Once the threshold has been reached you can switch a digital output
DOR.
1. Use «Up» or «Down» to select the
DOR line.
2. Press «Enter».
The
DOR output display flashes.
3. Select the output with the «Up» and «Down» keys.
4. Press «Enter».
The setting is applied.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.10.3.1 p1
Menu
active:
☐
······························
SP:
0.40bar ¦ SD:
−0.2bar
Switching point (SP) and switching differential (SD)
td
120s ¦ Logic
+
Delay (td) and logic
DOR1.03
ok ☑
Output DOR
DOT1.01
☐
Output DOT
5. Press the «Right» key.
6. Press «Enter».
The check box assigned to the output flashes.
7. Press the «Up» key.
The check box is activated.
8
Initial Start-up
8.8
Setting input and output signals
130
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
No.: 901700 14 E