2. Use «Up» or «Down» to select the
Pressures line.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
2 Performance data
Menu
▶1 Pressures
Active line
▶2 Temperatures
▶3 Speeds
▶4 External values
▶5 Curves
▶6 Frequency converter
3. Press «Enter».
The analogue data for pressures are displayed.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
2.1 Pressures
Menu
p1
0.0bar
Active line with inlet pressure
p2
0.0bar
dp
0.0bar
π = p2_a / p1_a
0.0
------------------------------
Drag indicator
4. Press «Escape» repeatedly to leave this menu.
➤ Display other analogue values in the same manner.
9.6 Displaying operating data
The following information can be called up in the
Operating data menu:
■
Operating hours
─
Blower package: Total machine running time
─
On load: Machine running time in LOAD mode
─
Motor: Running time of drive motor (adjustable)
─
Block: Running time of blower block (adjustable)
─
SIGMA CONTROL 2: Controller running time
─
OFC/SFC: FC block drive: Running time of the frequency converter
■ kWh counter
Display the operating hours
Precondition The operating mode is displayed.
9
Operation
9.6
Displaying operating data
No.: 901700 14 E
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X