8. Press «Enter».
The output is assigned and activated.
ok is displayed.
8.8.3.4 Setting the message type
1. Select the message type line with the «Up» and «Down» keys.
2. Press «Enter».
The display for the message type flashes.
3. Use «Up» or «Down» to set the message type.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.10.3.1 p1
Menu
······························
SP:
0.40bar ¦ SD:
−0.2bar
Switching point (SP) and switching differential (SD)
td
120s ¦ Logic
+
Delay (td) and logic
DOR1.03
ok ☑
Output DOR
DOT1.01
☐
Output DOT
Warning
☑
Type of message
4. Press «Enter».
5. Press the «Right» arrow.
6. Press «Enter».
The check box assigned to the message type flashes.
7. Press «Up» key.
The message is activated.
8. Press «Enter».
Result The message type is set and activated.
8.8.3.5 Activating the threshold
1. Use «Up» or «Down» to select the
active: line.
2. Press «Enter».
The check box will flash.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.10.3.1 p1
Menu
active:
☑
active line with check box
······························
SP:
0.40bar ¦ SD:
−0.2bar
Switching point (SP) and switching differential (SD)
td
120s ¦ Logic
+
Delay (td) and logic
DOR1.03
ok ☑
Output DOR
DOT1.01
☐
Output DOT
3. Press the «Up» key.
The check box is activated.
8
Initial Start-up
8.8
Setting input and output signals
No.: 901700 14 E
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
131