8.6.7 Flow rate control
With the operating mode
Flow rate control, it is possible to vary the flow rate through adjustments
to the airend speed.
This always refers to the intake volume. As a reference, the flow rate can be based on either inlet
conditions or standard conditions.
The SIGMA CONTROL 2 calculates the flow rate from the airend speed, with the aid of measured
values and machine-dependent parameters.
As per DIN, standard conditions are defined as follows:
■ Temperature: 0 °C
■ Pressure 1.01325 bar
■ Relative humidity 0%
As per CAGI, standard conditions are defined as follows:
■ Temperature: 20 °C
■ Pressure 1.01325 bar
■ Relative humidity 36%
The following parameters are adjustable:
Parameter
Available settings
Reference
Intake conditions
Standard conditions
Set value source
Local
AII1.02
Tab. 65 Parameters for the flow rate
Precondition The operating display is shown
Access level 2 is activated
1. Open the menu 5.4
<Configuration – Operating modes>.
2. Press the «Enter» key.
The current operating mode flashes.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4 Operating modes
Menu
Flow rate control
Current operating mode
------------------------------
▶1 Fixed speed
Submenu
▶2 Pressure control
Submenu
▶3 External values control
Submenu
▶4 Flow rate control
Submenu
3. Use the «Up» or «Down» key to set the operating mode
Flow rate control.
4. Press the «Enter» key.
The setting is applied accordingly.
5. Using the «Up» or «Down» key, select the line
▶4 Flow rate control.
8
Initial Start-up
8.6
Operating modes in frequency-controlled machines
No.: 901700 14 E
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
103