TempScan / MultiScan User's Manual
Chapter 4: Exp/11A Expansion Unit 35
Exp/11A Specifications
CAUTION
CAUTION
CAUTION
CAUTION
Please read this manual carefully! If equipment is used in any manner not
specified in this manual, the protection provided by the equipment may be
impaired.
Note:
These specifications are subject to change without notice.
Installation Category:
For CE:
Category 2 for Line Voltage Input terminal. All other terminals
are Category 1.
Master/Slave Port:
Female DB25 (2).
Number of Slots:
Ten (10).
Number of Channels (TempScan/1100):
Up to 320 differential voltage or thermocouple inputs, or up
to 160 RTD inputs; accepts any combination of ten (10) TempTC/32B, TempV/32B or
TempRTD/16B scanning modules.
Number of Channels (MultiScan/1200):
Up to 240 differential voltage or thermocouple inputs;
accepts any combination of ten (10) MTC/24 and MHV/24 scanning modules.
Channel to System Isolation:
60V peak.
Dimensions:
425mm wide x 305mm deep × 135mm high (16.75” × 12” × 5.75”).
Weight:
6.36 kg. (14 lbs.).
Operating Environment:
For standard:
Indoor use, 0 to 50°C; 0 to 95% RH (non-condensing) to
35°C; linearly derate 3% RH/°C from 35 to 50°C;
For CE:
Indoor use at altitudes below 2000
m, 0 to 40
°°°°
C; 0 to 80% RH up to 31
°°°°
C decreasing linearly 4% RH/
°°°°
C to 40
°°°°
C.
Controls:
Power Switch (external), DIP switch for setting slave ID (external).
Front Panel Indicators:
LED indicators for SCAN, ERROR, and POWER.
Power:
105-125 or 210-250 VAC, 50/60 Hz; 20 VA maximum
CAUTION
CAUTION
CAUTION
CAUTION
Line Voltage: The protective conductor terminal on the AC line connector must
be connected to an external protective earthing system. Failure to make such a
connection will impair protection from shock.
WARNING
WARNING
WARNING
WARNING
Service: This product contains no operator serviceable parts. Service must be
performed by qualified personnel. All terminals, including the AC line and
scanning cards, must be disconnected prior to opening the Exp/11A case. Internal
voltage potentials exist which could cause bodily injury or death!
Fuse:
1/2A, 250 V, Slo Blo, 3AG (for 105-125V power line) or 1/4A, 250V, Slo Blo, 3AG (for 210-
250V power line).
CAUTION
CAUTION
CAUTION
CAUTION
Fuse Failure: Fuse failure indicates a possible problem within the device circuitry.
If a fuse blows, contact a qualified service representative. Replacement fuses are
to be installed by qualified service personnel with the unit disconnected from the
power source and with all other terminals disconnected. If the line voltage selector
is changed, then the fuse designated for that line voltage must be used.
Содержание MultiScan 1200
Страница 2: ...TempScan MultiScan User s Manual...
Страница 4: ...TempScan MultiScan User s Manual...
Страница 10: ...vi TempScan MultiScan User s Manual Notes...
Страница 20: ...10 Chapter 1 System Overview TempScan MultiScan User s Manual Notes...
Страница 106: ...96 Chapter 8 ChartView ChartView Plus TempScan MultiScan User s Manual Notes...
Страница 130: ...120 Chapter 9 TempView TempScan MultiScan User s Manual...
Страница 150: ...140 Chapter 9 TempView TempScan MultiScan User s Manual Notes...
Страница 166: ...156 Chapter 10 PostView TempScan MultiScan User s Manual Notes...
Страница 234: ...224 Chapter 13 System Operation TempScan MultiScan User s Manual Notes...
Страница 248: ...238 Chapter 14 System Calibration TempScan MultiScan User s Manual Notes...
Страница 284: ...274 Chapter 15 Program Examples TempScan MultiScan User s Manual Notes...
Страница 330: ...320 Chapter 16 API Command Reference TempScan MultiScan User s Manual...
Страница 342: ...332 Chapter 16 API Command Reference TempScan MultiScan User s Manual...
Страница 358: ...348 Appendix TempScan MultiScan User s Manual Notes...
Страница 364: ...354 Index TempScan MultiScan User s Manual Notes...