Sample Type
The method of sampling the selected variable and calculating the value to be compared against the
thresholds. Possible sample types:
Absolute:
Get the sample directly.
Delta:
Calculate the difference between samples (default).
Value
The value of the statistic during the last sampling period.
Startup Alarm
The method of sampling the selected variable and calculating the value to be compared against the
thresholds. Possible sample types:
Rising:
Trigger alarm when the first value is larger than the rising threshold.
Falling:
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling:
Trigger alarm when the first value is larger than the rising threshold or less than the
falling threshold (default).
Rising Threshold
Rising threshold value (-2147483648 – 2147483647).
Rising Index
Rising event index (1 – 65535).
Falling Threshold
Falling threshold value (-2147483648 – 2147483647)
Falling Index
Falling event index (1 – 65535).
Buttons
Add new entry:
Click to add a new community entry.
Save:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved values.
Содержание 560931
Страница 1: ...16 PORT PoE WEB MANAGED GIGABIT ETHERNET SWITCH WITH 2 SFP PORTS MODEL 560931 INT 560931 UM 10 14 01...
Страница 25: ...25...
Страница 31: ...31 4 4 1 2 Security Switch Privilege Level Configuration This page provides an overview of the privilege levels...
Страница 190: ...190 Note 2 While the firmware uploading process is started don t shut down the switch...
Страница 276: ...276 Cross D Abnormal cross pair coupling with pair D Length The length in meters of the cable pair...