6.2.3 VeriPHY Cable Diagnostic
This page is used for running the VeriPHY Cable Diagnostics.
Select the port and then press
Start
to run the diagnostics. This will take approximately 5 seconds. If all
ports are selected, this can take approximately 15 seconds. When completed, the page refreshes
automatically, and you can view the cable diagnostics results in the cable status table. Note that
VeriPHY is only accurate for cables lengths of 7-140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10
or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Port
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status
Port:
Port number.
Pair:
The status of the cable pair.
The status of the cable pair.
OK - Correctly terminated pair
Open - Open pair
Short - Shorted pair
Short A - Cross-pair short to pair A
Short B - Cross-pair short to pair B
Short C - Cross-pair short to pair C
Short D - Cross-pair short to pair D
Cross A - Abnormal cross-pair coupling with pair A
Cross B - Abnormal cross-pair coupling with pair B
Cross C - Abnormal cross-pair coupling with pair C
Содержание 560931
Страница 1: ...16 PORT PoE WEB MANAGED GIGABIT ETHERNET SWITCH WITH 2 SFP PORTS MODEL 560931 INT 560931 UM 10 14 01...
Страница 25: ...25...
Страница 31: ...31 4 4 1 2 Security Switch Privilege Level Configuration This page provides an overview of the privilege levels...
Страница 190: ...190 Note 2 While the firmware uploading process is started don t shut down the switch...
Страница 276: ...276 Cross D Abnormal cross pair coupling with pair D Length The length in meters of the cable pair...