Rate
Controls the rate for the policer. The default value is 500. This value is restricted to 100-1000000 when
the "Unit" is "kbps" or "fps," and it is restricted to 1-3300 when the "Unit" is "Mbps" or "kfps."
Unit
Controls the unit of measure for the policer rate as kbps, Mbps, fps or kfps . The default value is "kbps."
Buttons
Save:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved values.
4.17.3 QoS / Port Scheduler
This page provides an overview of QoS Egress Port Schedulers for all switch ports.
The ports belong to the currently selected stack unit, as reflected by the page header.
The displayed settings:
Port
The logical port for the settings contained in the same row.
Click on the port number in order to configure the schedulers.
Mode
Shows the scheduling mode for this port.
Qn