Information:
poeswitch:/System>log level inf
Warning:
poeswitch:/System>log level war
Error:
poeswitch:/System>log level err
Clear Syslog
Syntax:
System Log Clear [all|info|warning|error]
poeswitch:/System>log clear all
System Log
Configuration
poeswitch:/System>log conf
System Log Configuration:
=========================
System Log Server Mode : Enabled
System Log Server Address : 192.168.2.100
System Log Level : Error
5.2 Power Reduction
Feature
Command Line
LED Power Reduction
LED Intensity Times
Syntax:
led_power timers [<hour>] [<intensity>]
Parameters:
<hour> : The hour (0-24) at which to change LEDs intensity
<intensity>: The LED intensity in % (0-100)
Example: (Time=2:00, Intensity: 30%)
led_power>timer 2 30
Maintenance
Syntax
:
led_power maintenance [<maintenance_time>]
[on_at_errors|leave_at_errors]
Parameters
:
<maintenance_time> : Time in seconds (0-65535) that the
LEDs shall be turned on, when any port changes link state
on_at_errors|leave_at_errors: on_at_error if LEDs shall be
turned on if any errors has been detected. leave_at_errors if
no LED change shall happen when errors have been detected
Example
:
led_power>main 20
led_power>main 20 on (20 sec., on_ad_errors enabled)
EEE Configuration
Содержание 560931
Страница 1: ...16 PORT PoE WEB MANAGED GIGABIT ETHERNET SWITCH WITH 2 SFP PORTS MODEL 560931 INT 560931 UM 10 14 01...
Страница 25: ...25...
Страница 31: ...31 4 4 1 2 Security Switch Privilege Level Configuration This page provides an overview of the privilege levels...
Страница 190: ...190 Note 2 While the firmware uploading process is started don t shut down the switch...
Страница 276: ...276 Cross D Abnormal cross pair coupling with pair D Length The length in meters of the cable pair...