![Intellinet 560931 Скачать руководство пользователя страница 221](http://html1.mh-extra.com/html/intellinet/560931/560931_user-manual_2074478221.webp)
221
20 entries from the beginning of the Dynamic ARP Inspection Table.
The "Start from port address," "VLAN," "MAC address" and "IP address" input fields allow the user to
select the starting point in the Dynamic ARP Inspection Table. Clicking the button will update the
displayed table starting from that or the closest next Dynamic ARP Inspection Table match. In addition,
the two input fields will — upon a button click — assume the value of the first displayed entry, allowing
for continuous refresh with the same start address.
The last entry of the currently displayed table is used as a basis for the next lookup. When the end is
reached, "No more entries" is shown in the displayed table. Use the button to start over.
ARP Inspection Table Columns
Port
Switch Port Number for which the entries are displayed.
VLAN ID
VLAN ID in which the ARP traffic is permitted.
MAC Address
User MAC address of the entry.
IP Address
User IP address of the entry.
Buttons
Auto-refresh:
Click this box to enable an automatic refresh of the page at regular intervals.
Refresh:
Click to refresh the page immediately.
Clear:
Flushes all dynamic entries.
/<< :
Updates the table starting from the first entry in the Dynamic ARP Inspection Tables.
>> :
Updates the table, starting with the entry after the last entry currently displayed.
Содержание 560931
Страница 1: ...16 PORT PoE WEB MANAGED GIGABIT ETHERNET SWITCH WITH 2 SFP PORTS MODEL 560931 INT 560931 UM 10 14 01...
Страница 25: ...25...
Страница 31: ...31 4 4 1 2 Security Switch Privilege Level Configuration This page provides an overview of the privilege levels...
Страница 190: ...190 Note 2 While the firmware uploading process is started don t shut down the switch...
Страница 276: ...276 Cross D Abnormal cross pair coupling with pair D Length The length in meters of the cable pair...