136
IE
3.19 VARIABLE HEAT OUTPUT.
N.B.:
the pressures indicated in the table represent the pressure differences
at the ends of the Venturi mixer and can be measured from the pressure
points in the upper part of the sealed chamber (Part. 17 and 18 Fig. 1-23).
The adjustments must be performed using a digital differential manometer
with a scale in tenths of mm or Pascal. The power data in the table has been
obtained with intake-exhaust pipe measuring 0.5 m in length. Gas flow rates
refer to heating values below a temperature of 15°C and at a pressure of 1013
mbar. Burner pressure values refer to use of gas at 15°C.
Victrix X 12 2 I.
Victrix X 24 2 I.
METHANE (G20)
BUTANE (G30)
PROPANE (G31)
HEAT
OUTPUT
HEAT
OUTPUT
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
(kW)
(kcal/h)
(m
3
/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
(kg/h)
(mbar) (mm H
2
O)
26,0
22360
D.H.W.
2,82
6,18
63,1
2,11
6,19
63,1
2,07
7,47
76,2
25,0
21500
2,71
5,63
57,4
2,02
5,65
57,6
1,99
6,85
69,9
24,0
20640
2,60
5,11
52,2
1,94
5,15
52,5
1,91
6,27
63,9
23,6
20296
CEN.
HEAT.
+
D.H.W.
2,55
4,92
50,1
1,91
4,96
50,5
1,87
6,04
61,6
22,0
18920
2,38
4,16
42,5
1,77
4,22
43,1
1,74
5,19
52,9
21,3
18354
2,30
3,88
39,5
1,72
3,94
40,2
1,69
4,86
49,5
20,0
17200
2,16
3,33
33,9
1,61
3,40
34,7
1,58
4,23
43,1
19,0
16340
2,05
2,95
30,0
1,53
3,03
30,9
1,51
3,79
38,6
18,0
15480
1,94
2,59
26,4
1,45
2,68
27,3
1,43
3,37
34,4
17,0
14620
1,84
2,26
23,1
1,37
2,36
24,0
1,35
2,99
30,5
16,0
13760
1,73
1,96
20,0
1,29
2,05
20,9
1,27
2,63
26,8
15,0
12900
1,62
1,68
17,1
1,21
1,78
18,1
1,19
2,29
23,4
14,0
12040
1,52
1,42
14,5
1,13
1,52
15,5
1,11
1,98
20,2
13,0
11180
1,41
1,18
12,1
1,05
1,28
13,1
1,03
1,69
17,3
12,0
10320
1,30
0,97
9,9
0,97
1,07
10,9
0,96
1,43
14,6
11,0
9460
1,20
0,79
8,0
0,89
0,88
9,0
0,88
1,19
12,2
10,0
8600
1,09
0,62
6,3
0,81
0,71
7,3
0,80
0,98
10,0
9,0
7740
0,98
0,48
4,9
0,73
0,56
5,7
0,72
0,79
8,0
8,0
6880
0,88
0,36
3,7
0,65
0,44
4,5
0,64
0,62
6,3
7,0
6020
0,77
0,27
2,7
0,57
0,33
3,4
0,56
0,48
4,9
6,0
5160
0,66
0,19
2,0
0,49
0,25
2,6
0,49
0,36
3,7
5,0
4300
0,55
0,15
1,5
0,41
0,19
2,0
0,41
0,26
2,7
4,0
3440
0,44
0,12
1,2
0,33
0,15
1,6
0,33
0,19
2,0
3,0
2580
0,33
0,12
1,2
0,25
0,14
1,4
0,25
0,15
1,5
METHANE (G20)
BUTANE (G30)
PROPANE (G31)
HEAT
OUTPUT
HEAT
OUTPUT
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
BURNER GAS
FLOW RATE
PRESS. BURNER
NOZZLES
(kW)
(kcal/h)
(m
3
/h)
(mbar)
(mm H
2
O)
(kg/h)
(mbar)
(
mm H
2
O)
(kg/h)
(mbar)
(
mm H
2
O)
12,0
10320
1,30
5,69
58,0
0,97
5,33
54,3
0,95
6,59
67,2
11,0
9460
1,19
4,75
48,4
0,89
4,45
45,4
0,87
5,50
56,0
10,0
8600
1,08
3,91
39,8
0,81
3,67
37,5
0,79
4,52
46,1
9,8
8456
1,06
3,78
38,5
0,79
3,55
36,2
0,78
4,37
44,6
8,0
6880
0,87
2,50
25,5
0,65
2,36
24,1
0,64
2,90
29,5
7,0
6020
0,76
1,92
19,6
0,57
1,82
18,6
0,56
2,23
22,7
6,0
5160
0,66
1,43
14,5
0,49
1,36
13,8
0,48
1,65
16,8
5,0
4300
0,55
1,00
10,2
0,41
0,96
9,8
0,40
1,16
11,9
4,0
3440
0,44
0,66
6,7
0,33
0,63
6,4
0,33
0,76
7,8
3,0
2580
0,34
0,39
4,0
0,25
0,37
3,8
0,25
0,45
4,6
2,0
1720
0,23
0,20
2,0
0,17
0,19
1,9
0,17
0,23
2,4
1,9
1634
0,22
0,19
1,9
0,16
0,18
1,8
0,16
0,22
2,2
Содержание VICTRIX X 12 2 I
Страница 2: ......
Страница 3: ...1...
Страница 96: ...94...
Страница 136: ...134 IE BG SK 3 5 A A B B Part A Part B 1 2 2 3 4 4 5 5 9 8 8 8 9 6 6 7 7 Part B as B B Part A as A A...
Страница 144: ...142...
Страница 145: ......
Страница 146: ...www immergas com This instruction booklet is made of ecological paper Cod 1 027728 Rev 15 028099 001 11 08...