Table 17. Common firmware error codes (continued)
Error code Description
Action or
possible failing FRU
B1xx 4660 Memory subsystem failure
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
B1xx 4661 Memory card VPD failure
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
B1xx 4662 DIMM VPD failure
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
B1xx 4670 Processor drawer cooling
1. Check ambient temperature.
2. Check air supply to fans.
3. Check fans for proper installation and
operation.
4. Check for any unsupported cards (that might
be too hot).
5. CEC backplane
Location code: U0.1-P1
B1xx 4671 Critical temperature in CEC drawer
1. Check ambient temperature.
2. Check air supply to fans.
3. Check fans for proper installation and
operation.
4. Check for unsupported cards (which might
be too hot).
5. CEC planar, U0.1-P1
B1xx 4672 Critical temperature in I/O subsystem
1. Check ambient temperature.
2. Check air supply to fans.
3. Check fans for proper installation and
operation.
4. Check for unsupported cards (which might
be too hot).
5. I/O subsystem planar, U0.dd-P1
B1xx 4681 JTAG scan interface
1. JTAG cabling
2. CEC backplane
Location code: U0.1-P1
3. Processor card
Location code: U0.1-P1-C1
B1xx 4682 Problem with system VPD on operator panel.
1. Replace the operator panel, location:
U0.1-L1. Do not swap the old VPD module
onto the new operator panel. Call service
support for instructions on programming the
new VPD module.
2. Call service support.
Chapter 5. Error code to FRU index
233
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...