MAP 1542: I/O Problem Isolation
This MAP is used to locate defective FRUs not found by normal diagnostics. For this procedure,
diagnostics are run on a minimally configured system. If a failure is detected on the minimally configured
system, the remaining FRUs are exchanged one at a time until the failing FRU is identified. If a failure is
not detected, FRUs are added back until the failure occurs. The failure is then isolated to the failing FRU.
This I/O problem-determination MAP isolates I/O card and I/O subsystem failures. When I/O problem
isolation is complete, all cables and cards exhibiting a failure will have been replaced or reseated.
Notes:
1. This MAP assumes that a Diagnostics CD-ROM is available.
2. If a general-access password or privileged-access password is installed, you are prompted to enter the
password before the diagnostic CD-ROM can load.
3. The term
POST indicators
refers to the device mnemonics (words
memory
,
keyboard
,
network
,
SCSI
, and
speaker
) that appear on the system console during the power-on self-test (POST).
4. The service processor might have recorded one or more symptoms in its error log. It is a good idea to
examine that error log before proceeding. (See “Accessing system error logs” on page 36.)
5. The service processor might have been set by the user to monitor system operations and to attempt
recoveries. You can disable these actions while you diagnose and service the system. If you disable
them, make notes of their current settings so that you can restore them easily. The following table lists
the settings:
Surveillance
From the service processor Setup Menu, go to the
Surveillance Setup Menu and disable surveillance.
Unattended start
From the service processor System Power Control Menu,
disable unattended start mode.
Reboot policy
From the System Power Control Menu, go to the
Reboot/Restart Policy Setup Menu and set:
a. Number of reboot attempts to
0
(zero).
b. Use OS-Defined restart policy to
No.
c. Enable supplemental restart policy to
No
.
Call out
From the Call-In/Call-Out Setup Menu, go to the Serial
Port Selection Menu and disable call-out on serial port
S2.
The steps in this procedure will attempt to slow boot the system into service mode diagnostics. The
following procedure describes booting a system with an attached console.The following procedure requires
booting standalone diagnostics (5 key between the
keyboard
and
speaker
indicators).
72
NAS Gateway 500 Service Guide
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...