Table 10. Firmware checkpoints (continued)
Checkpoint
Description
Action or
possible failing FRU
E527
Enable the memory MAP and I/O MAP for
the current RIO hub port
1. Check for system firmware updates.
2. Replace the riser card specified by the
location code.
3. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E52F
End of configuration of the RIO hub
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E528
Begin search for the next available I/O
drawer from a current RIO port
Replace the CEC backplane, U0.1-P1.
E529
Enable the control port and driver of the
current RIO hub
Replace the CEC backplane, U0.1-P1.
E52A
Search for the next available I/O drawer
from a current RIO port
Replace the CEC backplane, U0.1-P1.
E52B
The RIO cable connected to the RIO port
has been detected
Replace the CEC backplane, U0.1-P1.
E530
Checking RIO hub ports on current RIO
hub
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E531
Get RIO hub node ID
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E532
RIO cable detected; enable the RIO hub
port
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E533
Set up the RIO hub routing table
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E534
Get the node ID of the node on the other
end of the RIO cable
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E535
Valid node ID detected at other end of the
RIO cable
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E536
I/O subsystem detected at other end of the
RIO cable
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
Chapter 4. Checkpoints
109
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...