Table 10. Firmware checkpoints (continued)
Checkpoint
Description
Action or
possible failing FRU
E537
Configuring the I/O subsystem
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E538
Detected the RIO hub on the other end of
the RIO cable
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E539
Enabling the RIO hub ports
1. Check for system firmware updates.
2. Replace the riser card specified by the
location code.
3. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E53A
Set up the RIO port speed of the exit port
of the I/O subsystem connected to the RIO
hub port
1. Replace the riser card that the failing
drawer is attached to.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E53B
End of looking for next node port
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E53C
End of looking for next RIO hub port
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E53D
Disable the anynode mode
Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E540
Begin initialization of I/O drawer
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E541
Initialize the routing table
1. Replace the I/O subsystem planar
specified by the location code.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E544
Enable the RIO ports
Replace the I/O subsystem planar specified
by the location code.
E545
Set up the device routing address for this
new node ID
Replace the I/O subsystem planar specified
by the location code.
E546
Set up the RIO interface chip new node ID
Replace the I/O subsystem planar specified
by the location code.
E547
Set up the RIO interface chip routing table
Replace the I/O subsystem planar specified
by the location code.
E548
Disable any node mode
Replace the I/O subsystem planar specified
by the location code.
E549
Adjust RIO hub table
Replace the I/O subsystem planar specified
by the location code.
110
NAS Gateway 500 Service Guide
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...