hang at one of the checkpoints without displaying an 8-character error code. It is for these hang
conditions, only, that any action should be taken with respect to checkpoints. The most appropriate action
is included with each checkpoint.
Before taking actions listed with a checkpoint, check for additional symptoms in the service processor error
log. See “Accessing system error logs” on page 36 for information on how to access the service processor
error log.
Notes:
1. Go to “MAP 1548: Processor Subsystem Problem Isolation” on page 77 for any of the following
checkpoint hang conditions:
v
A four-digit code in the range of 8xxx-E4FF, E5Ex, or E700-EFFF that is not listed in the checkpoint
tables.
v
A four-digit code in the range of 8xxx-E4FF, E5Ex, or E700-EFFF that is listed in the checkpoint
tables but does not contain a repair action or FRU listing.
v
A four-digit code in the range of 8xxx-E4FF, E5Ex, or E700-EFFF, in which all of the FRUs listed
have been replaced or service actions have been performed and the problem has not been
corrected.
2. Go to “MAP 1542: I/O Problem Isolation” on page 72 for any of the following checkpoint hang
conditions:
v
A four-digit code in the range of E500 through E6FF (except E5Ex - see note 1 above) that is not
listed in the checkpoint tables.
v
A four-digit code in the range of E500 through E6FF (except E5Ex - see note 1 above) that is listed
in the checkpoint tables but does not contain a repair action or FRU listing.
v
A four-digit code in the range of E500 through E6FF (except E5Ex - see note 1 above), in which all
of the FRUs listed have been replaced or service actions have been performed and the problem has
not been corrected.
Checkpoints listed in the following tables are in the format 8xxx, 9xxx, Axxx, Bxxx, or Exxx, where x is any
hexadecimal digit from 1-9 or A-F. If your system hangs with a checkpoint displayed that begins with
anything other than 8, 9, A, B, or E, go to the
RS/6000
Eserver
pSeries Diagnostic Information for
Multiple Bus Systems
.
Use the following table to determine where to find the checkpoint.
Symptom
Action
You have a code that is of the form 8xxx, 9xxx, Axxx, or
Bxxx.
Go to “Service processor checkpoints”.
You have a code of the form Exxx.
Go to “Firmware checkpoints” on page 101.
You have a four-character code that is
not
of the form
8xxx, 9xxx, Axxx, Bxxx, or Exxx.
Refer to the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
manual.
Service processor checkpoints
Service processor checkpoints are in the range 8xxx to Bxxx. The message
OK
indicates successful
service processor testing and initialization. Firmware checkpoints are listed in “Firmware checkpoints” on
page 101.
Notes:
1. A spinning (or twirling) slash is displayed in the upper-right corner of the operator panel while some
checkpoints are being displayed. If the slash stops spinning, this indicates a hang condition.
2. Not all service processor checkpoints are supported.
94
NAS Gateway 500 Service Guide
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...