Table 10. Firmware checkpoints (continued)
Checkpoint
Description
Action or
possible failing FRU
E70D
Create VPD.
1. Check for system firmware updates.
2. Call service support.
E70F
Collect CEC VPD.
Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E7EE
Delaying while waiting for power subsystem
VPD collection to be completed;
informational only
1. Check for system firmware updates.
2. Call service support.
E7FF
Successful end of VPD creation
Informational message. If the system hangs
here, go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E800
RTAS initialization problem
1. Check for system firmware updates.
2. Call service support.
E841
Initializing RTAS/open firmware device tree
interface
1. Check for system firmware updates.
2. Call service support.
E842
Initializing RTAS/service processor interface 1. Check for system firmware updates.
2. Replace the CEC backplane
Location: U0.1-P1.
3. Call service support.
E843
Initializing RTAS/sensor interface
1. Check for system firmware updates.
2. Call service support.
E844
Initializing RTAS/time-of-day clock interface
1. Check for system firmware updates.
2. Replace the CEC backplane
Location: U0.1-P1.
3. Call service support.
E845
Initializing interface/sensor access
1. Check for system firmware updates.
2. Call service support.
E846
Initializing interface/sensor access
1. Check for system firmware updates.
2. Call service support.
E84F
Initializing RTAS/operator panel interface
1. Check for system firmware updates.
2. Call service support.
E850
Initializing RTAS/cache interface
1. Check for system firmware updates.
2. Call service support.
E851
Initializing RTAS/hardware access
1. Check for system firmware updates.
2. Call service support.
E852
Initializing RTAS/PCI bus interface
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
3. Call service support.
120
NAS Gateway 500 Service Guide
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...