Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
4066 0EB9 Attention line 8 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
4066 0EBA Attention line 9 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
4066 0EBB Attention line 10 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
4066 0EBC Attention line 11 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
4066 0EE1 Service processor firmware: invalid MRU to FRU
mapping
1. Check for system firmware updates.
2. Call service support.
4066 0EE2 Service processor firmware fault
1. Check for system firmware updates.
2. Call service support.
4066 0EE5 Firmware error, no callout available
1. Check for system firmware updates.
2. Call service support.
4067 0001 Scan interface basic assurance tests detected a
CEC backplane fault.
CEC backplane
Location code: U0.1-P1
4067 0002 CEC backplane fault
1. Check JTAG cable connections.
2. CEC backplane
Location code: U0.1-P1
4067 0003 Scan interface basic assurance tests detected
processor fault.
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C1
4067 0004 Processor fault
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C2
4067 000E Processor capacity card
Operator panel
Location code: U0.1-L1
4067 0010 DIMM fault
DIMM
Location code: U0.1-P1-C1-M8
4067 0011 DIMM fault
DIMM
Location code: U0.1-P1-C1-M6
4067 0012 DIMM fault
DIMM
Location code: U0.1-P1-C1-M1
4067 0013 DIMM fault
DIMM
Location code: U0.1-P1-C1-M3
4067 0014 DIMM fault
DIMM
Location code: U0.1-P1-C1-M7
4067 0015 DIMM fault
DIMM
Location code: U0.1-P1-C1-M5
4067 0016 DIMM fault
DIMM
Location code: U0.1-P1-C1-M2
4067 0017 DIMM fault
DIMM
Location code: U0.1-P1-C1-M4
Chapter 5. Error code to FRU index
165
Содержание TotalStorage NAS Gateway 500
Страница 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 2: ......
Страница 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Страница 16: ...xiv NAS Gateway 500 Service Guide ...
Страница 20: ...xviii NAS Gateway 500 Service Guide ...
Страница 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Страница 52: ...32 NAS Gateway 500 Service Guide ...
Страница 58: ...38 NAS Gateway 500 Service Guide ...
Страница 68: ...Step 0410 13 This completes the repair return the system to the user 48 NAS Gateway 500 Service Guide ...
Страница 112: ...92 NAS Gateway 500 Service Guide ...
Страница 266: ...246 NAS Gateway 500 Service Guide ...
Страница 326: ...306 NAS Gateway 500 Service Guide ...
Страница 353: ...Chapter 11 Removal and replacement procedures 333 ...
Страница 392: ...372 NAS Gateway 500 Service Guide ...
Страница 394: ...System parts 1 5 6 9 10 11 12 8 7 13 4 15 16 17 18 19 20 14 3 2 374 NAS Gateway 500 Service Guide ...
Страница 396: ...System parts continued 1 12 13 3 10 12 8 15 14 14 16 18 19 17 7 9 11 4 4 5 6 2 376 NAS Gateway 500 Service Guide ...
Страница 402: ...382 NAS Gateway 500 Service Guide ...
Страница 412: ...392 NAS Gateway 500 Service Guide ...
Страница 440: ...420 NAS Gateway 500 Service Guide ...
Страница 446: ...426 NAS Gateway 500 Service Guide ...
Страница 448: ...428 NAS Gateway 500 Service Guide ...
Страница 466: ...446 NAS Gateway 500 Service Guide ...
Страница 469: ......
Страница 470: ... Printed in U S A GY27 0418 00 ...
Страница 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...