Table 9. Engine troubleshooting symptoms and actions (continued)
Error Symptom
CRU/action
Monitor problems (general).
Note:
Some monitors have their own self-tests. If you suspect a problem
with the monitor, refer to the information that comes with the monitor for
adjusting and testing instructions.Suggested action:
1.
Monitor
.
2. Run video diagnostics.
Note:
If the diagnostics complete successfully, the problem might be
a video driver.
3. Display adapter/system board.
Fixed disk diagnostic does not recognize
drives.
Test shows fewer drives than are
actually installed.
Remove first drive that does not appear and rerun diagnostic. If the
remaining drives show up, replace the removed drive.
Fixed disk diagnostic freezes when run.
Remove the drive being tested at the time of the freeze and rerun the
diagnostic. If the diagnostic completes successfully, replace the removed
drive.
Power problems
Power problems can be difficult to troubleshoot. For example, a short circuit can
exist anywhere on any of the power distribution busses. Usually a short circuit
causes the power subsystem to shut down because of an overcurrent condition.
Table 10 lists the power error messages that you might encounter.
A general procedure for troubleshooting power problems is as follows:
1. Power off the system and disconnect the AC cord(s).
Attention:
Note the special considerations when powering off and powering
on the Model 326 engine. See “Powering off and powering on the Model 326”
on page 49 for details.
2. Check for loose cables in the power subsystem. Also check for short circuits, for
example, if there is a loose screw causing a short circuit on a circuit board.
3. Remove adapters and disconnect the cables and power connectors to all
internal and external devices until the Model 326 engine is at minimum
configuration required for power on.
4. Reconnect the AC cord and power on the Model 326 engine. If the engine
powers up successfully, replace adapters and devices one at a time until the
problem is isolated. If the engine does not power up from minimal configuration,
replace FRUs of minimal configuration one at a time until the problem is
isolated.
Table 10. Power error messages
Message
Action
Power supply
X
current share fault
(level-critical; excessive current demand on
power supply
X
)
1.
See “Power problems”
Power supply
X
DC good fault
(level-critical; power good signal not detected
for power supply
X
)
1.
Replace power supply
X
Power supply
X
temperature fault
1.
Replace fan
X
Power supply
X
removed
1.
No action required - information only
Chapter 8. Troubleshooting
91
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...