Table 16. ServeRAID-4Lx problems and actions (continued)
Problem
Action
FFFF or other code not listed
1. Follow indications in the POST (ISPR)
error procedures (“POST (ISPR) error
procedures” on page 105).
2. SCSI cable.
3. SCSI backplane.
4. Hard drive.
5. Check the ServeRAID-4Lx controller.
Testing the ServeRAID 4Lx adapter
You can run all diagnostic operations for the ServeRAID adapters through the IBM
ServeRAID Configuration software in the
Advanced Functions
option. You can run
subsystem diagnostics through the system diagnostics.
Note:
Before running any test, back up the current disk array configuration using
the ServeRAID diagnostics test program. Always keep a current backup of
the ServeRAID configuration information. Dynamic changes might occur in
the configuration due to hot-spare replacement.
The IBM PC ServeRAID Adapter diagnostics test program runs from diskette,
independent of the operating system. You can obtain a copy from the ServerGuide
Diskette Factory or download the image from the IBM Web site.
To back up the ServeRAID configuration:
1. From the Main Menu, select
Advanced Functions
.
2. Select
Backup IPS ServeRaid Config
.
Use the ServeRAID Subsystem Diagnostic program to test the PC ServeRAID
Adapter and the devices connected to it. To test the ServeRAID subsystem:
1. Start the ServeRAID Configuration Utility program.
2. Select
Advanced Functions
from the Main Menu and press
Enter
.
3. Select
IBM ServeRAID Subsystem Diagnostic
from the next menu and press
Enter
.
4. Select the diagnostic test to run and press
Enter
. Descriptions of the diagnostic
tests available include:
Run Adapter Self-tests
Tests the PC ServeRAID Adapter. Restart the server after the self-test
completes.
SCSI Device Self-test
Runs diagnostic tests on the SCSI devices attached to the PC
ServeRAID Adapter.
Troubleshooting the SCSI HVD 3570 adapter
You can use the troubleshooting chart in Table 17 on page 108 to find solutions to
the HVD adapter problems that have definite symptoms.
Chapter 8. Troubleshooting
107
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...