Attaching to the serial port while the hub is on
1. If the hub is on, you can attach your service terminal, login, and run most
diagnostics. However, you need to get an administrator username and password
recognized by the hub from the system administrator.
2. After you get an administrator username, stop any Ethernet session active on
the Ethernet port.
3. Attach your service terminal to the serial port on the hub. The Ethernet port and
the serial port are mutually exclusive.
4. When prompted, log in with the appropriate username and password. The
password does not display as you type it in. The hub responds:
Username>
You can now type any diagnostic command and observe the results as they are
logged to your service terminal.
Running diagnostics from a Telnet session on the Ethernet
The easiest way to run diagnostics is through a LAN-attached server that can
access the hub Ethernet port.
You need to get an administrator-level username and password from the system
administrator, as well as the hub IP address or name.
Perform the following steps:
1. Go to the server with LAN access and, in an open window, type:
telnet
Ipaddress
or
name
(the hub IP address or name you were given by the system administrator)
2. Type the username you were given and press Enter. The hub responds:
Ipaddress
password
:
3. Type the password you were given. The hub responds:
Username>
You can now run any of the diagnostics and observe the results as the hub displays
them in your Telnet session.
Diagnostic tests during POST
Table 29 lists the diagnostic tests that are automatically run during POST.
Table 29. Hub POST diagnostic tests
Test
Checks
Memory test
CPU RAM memory.
Port register test
ASIC registers and SRAMs
Central memory test
System board SRAMs
CMI conn test
CMI bus between ASICs
CAM test
CAM
Port loopback test
All of the hub hardware: frames are
transmitted, looped back, and received
158
Model 326 User’s Reference
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...