as a field replaceable unit (FRU), resulting in a combination of PCI adapters that
includes three or more 10/100 Ethernet adapters and a ServeRAID adapter, the
system BIOS might write a power-on self test (POST)
001801xx Resource
Allocation Error
message to the error log. If a monitor is attached to the engine, the
message will also be displayed on the monitor.
This message will not cause actual operational problems with the appliance. The
engine will continue to boot to completion and will otherwise function normally.
However, each time you reboot the engine, the same message again will be written
to the error log and displayed on the monitor (if attached).
To eliminate these warning messages during POST, you can obtain a utility to
disable the 10/100 Ethernet adapter’s expansion ROM from the NAS support Web
site at http://www.ibm.com/storage/support/nas.
ServeRAID-4Lx problems and actions
Table 16 lists problems and corrective actions associated with the adapter. The
table helps you determine which adapters might need to be replaced at the
conclusion of troubleshooting procedures.
Note:
Do not replace any controllers until you have followed the POST (ISPR) error
procedures (see “POST (ISPR) error procedures” on page 105). Replace a
ServeRAID controller only when indicated to do so in the POST (ISPR) error
procedures.
XXX
in Table 16 is used as a placeholder and can be any letter or number in an
actual error message.
Table 16. ServeRAID-4Lx problems and actions
Problem
Action
1XXX (Microcode Checksum Error)
Check the ServeRAID-4Lx controller
2XXX through 5XXX (Code DRAM Error)
1. Install download jumpers, flash latest
level BIOS and firmware for controller.
2. Remove jumpers.
3. Check the ServeRAID-4Lx controller.
6XXX (Cache DRAM Error) (ServeRAID-4H
only)
1. Reseat daughter card.
2. Install download jumpers, flash latest
level BIOS and firmware for controller.
Remove jumpers.
3. Check the ServeRAID-4Lx controller.
7XXX through 8XXX (Host/Local PCI Bus
Interface Error)
1. Install download jumpers, flash latest
level BIOS and firmware for controller.
Remove jumpers.
2. Check the ServeRAID-4Lx controller.
9ZXX through BZXX SCSI Bus error caused
by cables, termination, defective drives, and
so on). The Z refers to the specific channel
or channels that cause the error.
1. Follow indications in the POST error
procedures (see “POST (ISPR) error
procedures” on page 105). Follow those
instructions before continuing with the
next steps listed in this table.
2. SCSI cable.
3. SCSI backplane.
4. Hard drive.
5. Check the ServeRAID-4Lx controller.
EFFE (Firmware code corrupt or download
jumpers are in place)
1. Flash latest level BIOS and firmware for
controller. Remove jumpers.
2. Check the ServeRAID-4Lx controller.
106
Model 326 User’s Reference
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...