1. Connect a serial cable that shipped with the hub (not null-modem) between the
serial port on the hub and COM1 of the system
2. Open a HyperTerminal Session from the managing system.
3. Choose a name for the session.
4. In the
Connect to
window, change to COM1.
5. Set properties as follows:
Bits/second
9600
Data bits
8
Parity
None
Stop bits
1
Flow control
None
Then click
OK
.
6. Connect and then press
Enter
on the terminal screen.
7. Type
qlshow
.
8. Write down the World Wide Name, for example: 10:00:00:60:69:30:18:00.
9. Remove the cable from the first Fibre hub and connect it to the partner hub.
10. Press
Enter
on the terminal screen.
11. Type
qlshow
.
12. Write down the World Wide Name, for example: 10:00:00:60:69:30:18:01
13. On this hub, type, including the quotes,
qlpartner “10:00:00:60:69:30:18:00”
(that is, the first hub’s WWN), and press
Enter
.
14. The hub saves the configuration and restarts.
15. Connect the cable back to the first fibre hub.
16. Press
Enter
on the terminal screen.
17. On the first hub, type, including the quotes,
qlpartner
“10:00:00:60:69:30:18:01”
(that is the partner hub’s WWN), and press
Enter
.
18. After the hub restarts, type
qlshow
to display the first hub and its partner
(peer).
Notes:
1. When viewing the connection on the 3534 Fibre-Managed Hubs, you will see
link lights on the interconnect fibre cable.
2. If using additional GBICs in the last port to partner the hubs, then the
qlshow
command will not display a status for the qlpartnering.
Setting IP Address of Fibre Hub and Fibre Switch
The following steps allow you to set an IP address for the Fibre hub and switch.
1. Connect a serial cable that shipped with the hub or switch (not null-modem)
between the serial port on the hub/switch and COM1 of the system
2. Open a HyperTerminal Session from the managing system.
3. Choose a name for the session.
4. On the
Connect to window
, change to COM1.
5. Set properties as follows:
Bits/second
9600
Data bits
8
156
Model 326 User’s Reference
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...