NVRAM Memory Test
Passed
Realtime Clock Test
Passed
Programmable Gate Array Test:
Passed
I2C Interface Test:
Passed
Main Application Checksum:
Passed
Boot Sector Checksum:
Passed
Onboard Ethernet Hardware Test:
Passed
PCI EEPROM Initialization Test:
Passed
5. When you finish viewing this information, press
Esc
to return to the main option
menu. Remove the CD, then restart the engine.
Testing SCSI adapters
The SCSI adapters are used for tape backup operations. You can test and
configure them during engine boot time by entering
Ctrl-A
when prompted. This
invokes the BIOS SCSI Select utility. Follow the on-screen directions when this
utility appears.
IBM 3534 Fibre Channel Hub Model 1RU
This section gives troubleshooting information for the IBM 3534 Fibre Channel Hub
Model 1RU.
Each hub port includes an LED indicator. If a problem has been detected with the
port, the LED indicators provide some indication of the type of problem. Faults and
problems are displayed with a yellow port indicator. The color and blink speed of
each port’s LED, as described in Table 18, indicates the status of each port.
Table 18. HUB front panel LED status indicators
Indicators
Status
No light showing
No light or signal carrier (no module, no
cable) for media interface LEDs.
Steady yellow
Receiving light or signal carrier, but attached
device not yet online.
Slow
1
yellow
Disabled (result of diagnostics or portDisable
command). Blinks every 2 seconds.
Fast
2
yellow
Error, fault with the port. Blinks every 1/2
second.
Steady green
Online (connected with device over cable)
Slow green
Online, but segmented (loopback cable or
incompatible switch). Blinks every 2 seconds.
Fast green
Internal loopback (diagnostic). Blinks every
1/2 second.
Flickering green
Online and frames are flowing through the
port.
Green and yellow
The port is bypassed.
Notes:
1.
Slow - blinks at 2 second intervals
2.
Fast - blinks at 1/2 second intervals
If a GBIC is not installed, no light shows on the LED. When a GBIC is installed and
a cable is connected to a properly functioning Fibre Channel device, the LED
Chapter 8. Troubleshooting
111
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...