Table 31. Hub diagnostic error messages (continued)
Message
Description
Probable cause
Action
DIAG-MEMORY Err#0110
[ramTest]
Data read from RAM
location did not match
previously written data into
same location.
CPU RAM failure
1
DIAG-PORTABSENT
Err#2670, 3070, 3870
[portLoopbackTest,
crossPortTest, spinSilk]
Port is not present.
ASIC or system
board failure
1
DIAG-PORTDIED Err#265F,
305F, 385F
[portLoopbackTest,
crossPortTest, spinSilk]
Port was in loopback mode
and then went inactive.
ASIC, GBIC
module, embedded
optic or fiber cable
failure
2
DIAG-PORTSTOPPED
Err#3874 [spinSilk]
Port is no longer
transmitting, as indicated by
the number of frames
transmitted counter being
stuck at N frames.
ASIC, GBIC
module, embedded
optic or fiber cable
failure
2
DIAG-PORTWRONG
Err#3078 [crossPortTest]
Frame erroneously received
by port M instead of the
intended port N.
ASIC failure
1
DIAG-POST_SKIPPED Err#
0004 [managed hub
initialization]
POST is skipped. Its
message recommended
that POST be executed.
Informational only
None
required
DIAG-REGERR Err#0B15,
0415 [portRegTest,
sramRetentionTest]
Data read from ASIC
register or ASIC SRAM did
not match data previously
written into same location.
ASIC failure
1
DIAG-REGERR_UNRST
Err#0B16, 0416 [portRegTest,
sramRetentionTest]
Port failed to unreset.
ASIC failure
1
DIAG-STATS Err#2660 - 2662,
3060 - 3062 [portLoopback
Test, crossPortTest]
Port counter value did not
match the number of
frames actually transmitted.
Possible counters reporting:
v
FramesTx - number of
frames transmitted
v
FramesRx - number of
frames received
v
Cl3FrmRx - number of
class 3 frames received
ASIC, GBIC
module, embedded
optic or fiber cable
failure
2
DIAG-TIMEOUT Err#266F,
306F, 386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
v
For portLoopbackTest
and crossPortTest: port
failed to receive frame
within time-out period.
v
For centralMemoryTest:
port failed to detect an
interrupt within the
timeout period.
ASIC, GBIC
module, embedded
optic or fiber cable
failure
2
DIAG-XMIT Err#2271, 2671,
3071, 3871
[portLoopbackTest,
crossPortTest, spinSilk,
camTest]
Port failed to transmit
frame.
ASIC failure
1
168
Model 326 User’s Reference
Содержание totalstorage 326
Страница 1: ...IBM TotalStorage Network Attached Storage 300 Model 326 User s Reference Release 2 5 GA27 4276 02...
Страница 8: ...viii Model 326 User s Reference...
Страница 10: ...x Model 326 User s Reference...
Страница 20: ...8 Model 326 User s Reference...
Страница 64: ...52 Model 326 User s Reference...
Страница 88: ...76 Model 326 User s Reference...
Страница 134: ...122 Model 326 User s Reference...
Страница 144: ...132 Model 326 User s Reference...
Страница 146: ...134 Model 326 User s Reference...
Страница 166: ...154 Model 326 User s Reference...
Страница 182: ...170 Model 326 User s Reference...
Страница 192: ...180 Model 326 User s Reference...
Страница 214: ...202 Model 326 User s Reference...
Страница 232: ...220 Model 326 User s Reference...
Страница 238: ...226 Model 326 User s Reference...
Страница 239: ......
Страница 240: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA27 4276 02...