Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
29B00004 Mouse not
present/detected.
Replace the I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2B200402 Unsupported
Processor.
1. Remove the CPU card in P1–C2 (farthest away from the memory cards). If
the problem is resolved, replace the removed CPU card. If not, continue.
2. Exchange the CPU card in P1–C1 (closest to the memory cards) with the
CPU card removed in step one. If the problem is resolved, replace the
removed CPU card. If not, continue.
3. Return both CPU cards to their original slots.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2B2xxx22 Processor disabled.
1. Remove the CPU card in P1–C2 (farthest away from the memory cards). If
the problem is resolved, replace the removed CPU card. If not, continue.
2. Exchange the CPU card in P1–C1 (closest to the memory cards) with the
CPU card removed in step one. If the problem is resolved, replace the
removed CPU card. If not, continue.
3. Return both CPU cards to their original slots.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Where xxx indicates the processor type as follows:
211
Vital Product Data corrupted. Call the next level of support.
261
166 MHz 2 way CPU card
461
332 MHz 2 way CPU card
868
255 MHz 2 way CPU card
For Model F10 and F20, see the Retain Tip for this error code or call
the next level of support. It may be possible to repair this error without
replacing the CPU card.
8A8
340 MHz 2 way CPU card
2B2xxx31 Processor failed.
See error code 2B2xxx22 for action.
2B2xxx42 Unsupported
processor type.
Replace with proper CPU Card.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
See error code 2B2xxx22 for action.
2BA00xxx Service Processor
Find exact error code in this table.
2BA00000 Service processor
POST failure.
1. Power off and on the cluster bay, retry the operation. Connect the service
terminal to the working cluster bay and use the Alternate Cluster Repair
Menu options to quiesce, power off, power on and resume the failing cluster
bay.
2. Replace the Service Processor Card (E10/E20 only).
3. Replace I/O Planar (E10/E20 and F10/F20).
The F10/F20 I/O planar includes the service processor.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00012 Service processor
reports self-test failure.
Refer to actions in error code 2BA00000.
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
81
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...