15. From the Screen Colors window place a check mark in the Allow Graphics Rendition Code of 0 to
Reset Colors to Default check box.
16. From the Screen Colors window, click on OK. You will be returned to the Phone Directory window.
17. From the Phone Directory window, click on Add.
18. From the Phone Directory window, click on OK.
19. Select the following service terminal option and go to the indicated page and step:
Normal Service Activities
– Service Login Operation Connection, with Cluster IML Complete step 2.
Service Terminal Connection Problems
For all service terminal connection problems see
″
MAP 6040: Service Terminal Login
″
or
″
MAP 6060:
Service Terminal Login
″
in chapter 3 of the Enterprise Storage Server Service Guide, Volume 1.
Service Login Operation Connection, with Cluster IML Complete
Do the following steps to activate Cluster Service Login following a completed Cluster IML (Operator panel
Cluster 1 or 2 Message indicator stops blinking):
Attention: The 2105 and cable in this procedure are ESD-sensitive. Always wear an ESD wrist strap
during this procedure. Follow the ESD procedures in
″
MAP 6060: Service Terminal Login
″
in chapter 4 of
the Enterprise Storage Server Service Guide, Volume 2.
1. Set the service terminal on the 2105 service table and start the appropriate terminal emulator (i.e.
EBTERM for OS/2 or NetTerm for Windows).
Use “Service Terminal Setup and 2105 Configuration Verification” on page 54 to prepare the service
terminal for service and to verify that the service terminal has been initialized to service the 2105.
2. Set the terminal emulator to the Direct Connect mode:
v
OS/2 Operating System:
a. At the EBTERM window, select and click on the Modify menu option.
b. At the Modify menu, verify that Direct Connect Mode has a check mark next to it. Set all other
check marks on this menu off.
Note: Single click to set check marks on or off.
c. Go to step 3.
v
Windows Operating System, at the NetTerm window, single click on File and then Phone
Directory
– If the Phone Directory displays IBM 2105 VSS/ESS (Direct Connect, IBM3151 emulation), the
service terminal is setup to run NetTerm as Direct Connect. Go to step 3.
– If the Phone Directory doesn’t display IBM 2105 VSS/ESS (Direct Connect, IBM3151
emulation), then the service terminal needs to be setup again. Go to “Service Terminal Setup
and 2105 Configuration Verification” on page 54 to prepare the service terminal for service and
go to step 3. when complete.
3. Verify that the 2105 Model Exx/Fxx is powered on. The 2105 Model Exx/Fxx operator panel Power
Complete indicator for the cluster bay you are attaching to should be on continuously.
4. Connect the service terminal to the cluster bay being serviced:
a. Connect the service terminal interface cable to the serial port connector (9 pin) on the service
terminal.
b. Connect the other end of the cable to the S2 connector on the cluster bay being serviced, cluster
bay 1 or cluster bay 2.
Note: The service terminal interface cable is stored in the 2105 Model Exx/Fxx rack or connected
to S2 on the front of cluster bay 1 or 2.
Service Terminal Setup
Service Terminal, CHAPTER 8
57
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...