Table 10. SP Checkpoints. (continued)
Checkpoint
Description
Action/ Possible Failing FRU
E080
Entering Service Processor emergency
firmware flash recovery process.
Call the next level of support before doing the
following:
1. I/O Planar, OR
2. Insert a new DOS formatted diskette
containing the service processor firmware
into the diskette drive. The image file
name must be spflash.img.
Note: ONLY insert the diskette after the
operator panel displays E080 code.
3. Power the cluster off then on and rerun
the flash recovery.
E081
Flash update completed - system reboot in
progress
1. Power the cluster off then on and rerun
the flash recovery.
2. Retry a service processor emergency
flash update (if possible) as documented
in the checkpoint code E080.
3. I/O Planar, see 1 on page 100
4.
5.
E0A0
Beginning Bring-Up Phase
1. Service Processor (E10/E20 only)
2. CPU Card
3. I/O Planar (See notes on 72 )
E0B0
Starting CPU BIST
1. CPU Card
2. I/O Planar (See notes on 72 )
3. Service Processor (E10/E20 only)
E0C0
Starting X5 BIST
1. CPU Card
2. I/O Planar (See notes on 72 )
3. Service Processor (E10/E20 only)
E0D0
Creating scan log is slow, wait for completion None
E0E0
Pulling CPU out of reset
1. CPU Card
2. I/O Planar (See notes on 72 )
3. Service Processor (E10/E20 only)
E0E1
Pull CPU out of reset: OK
1. CPU Card
2. I/O Planar
3. System Planar (See notes on 72 )
4. Service Processor (E10/E20 only)
E164
Create PCI graphics node (P9)
See 1 on page 100
E168
Create PCI graphics node (S3)
See 1 on page 100
E16C
GTX100P Subsystem Open request
See 1 on page 100
E16D
GTX100P planar not detected or failed
diagnostics
See 1 on page 100
E16E
GTX100P subsystem open successful
See 1 on page 100
E16F
GTX100P
See 1 on page 100
E240
Setup Winbond ISA bridge
I/O Planar, see 1 on page 100
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
103
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...