
Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
2BA00341 Service Processor
reports Locked fan -
Fast Shutdown request
fan number 2.
Refer to the actions in error code 2BA00300.
2BA00342 Service Processor
reports Locked fan -
Fast Shutdown request
fan number 3.
Refer to the actions in error code 2BA00300.
2BA00343 Service Processor
reports Locked fan -
Fast Shutdown request
fan number 4.
Refer to the actions in error code 2BA00300.
2BA00350 Service Processor
reports Generic
Immediate Shutdown
request.
1. Use the service terminal to display and repair any related power problems.
Use the Show / Repair Problems Needing Repair option.
2. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00351 Service Processor
reports Generic AC
power loss EPOW.
1. Use the service terminal to display and repair any related power problems.
Use the Show / Repair Problems Needing Repair option.
2. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00352 Service Processor
reports Loss of power.
Use the service terminal to display and repair any related power problems. Use
the Show / Repair Problems Needing Repair option.
1. Check electronics cage fans for obstructions that prevent them from normal
operation.
2. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00353 Service Processor
reports Loss of power.
1. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the other cluster. Use the Show / Repair
Problems Needing Repair option.
2. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00360
to
2BA00376
Service Processor
false power or cooling
error.
1. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the other cluster. Use the Show / Repair
Problems Needing Repair option.
2. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00399 Service Processor
reports Unsupported
value in EPOW.
Replace the I/O Planar
40100005 A loss of cluster bay
power detected.
Use the service terminal to display and repair any related power problems.
Connect the service terminal to the other cluster. Use the Show / Repair
Problems Needing Repair option.
40100007 Immediate shutdown.
See error code 40100005.
Codes
88
VOLUME 3, ESS Service Guide
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...