Service Request Number List
Table 12. Service Request Numbers
Service
Request
Number
SRN
Src.
Failing
Function
Codes
Description and Action
101-000
A
Description: The cluster bay hung while attempting to configure a device.
Action: Go to
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
101-185
A
Description: A Check-stop occurred.
Action: Go to
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
101-517
A
Description: The cluster bay failed to IPL.
Action: Go to
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
101-518
A
Description: CD-ROM read problems after boot.
Note: The boot record was read from the CD-ROM disk. However, errors
occurred when trying to mount the CD-ROM file system.
Action: Test the CD-ROM Drive. Boot from the SCSI Hard Drive (normal
cluster bay power on). Connect the service terminal, use Main Service
Menu, then Machine Test Menu, then CD-ROM Drive option.
101-521 to
101-538
A
Description: The configuration manager detected an error.
Action: Call the next level of support. (This information is for the next level
of support.) If you are running the diagnostics from the SCSI Hard Drive, try
running the diagnostics from a CD-ROM. If the diagnostics run correctly
from CD-ROM, the problem may be damaged data on the disk. Go to
″
MAP
4020: SCSI Hard Drive Build
″
in chapter 3 of the Enterprise Storage Server
Service Guide, Volume 1. If a different problem occurs when you run the
diagnostics from CD ROM, correct that problem. If you were running from a
CD ROM at first, or have the same problem on CD ROM that you had when
running diagnostics from disk then go to
″
MAP 4540: Cluster Minimum
Configuration
″
in chapter 3 of the Enterprise Storage Server Service Guide,
Volume 1.
101-544
A
Description: Disk read problems occurred after booting.
Note: The boot record was read from the disk. However, errors occurred
when trying to open the disk drive. This problem can be caused by SCSI
device addressing, SCSI terminator, open PTC, SCSI cable, etc.
Action: Go to
″
MAP 4020: SCSI Hard Drive Build
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
101-551 to
101-557
A
Description: The cluster bay hung while loading the software. This can be
caused by a hardware or software problem.
Action: Test the cluster bay. Connect the service terminal, use Main Service
Menu, then Machine Test Menu, then cluster bay. If no problem is found,
then go to
″
MAP 4020: SCSI Hard Drive Build
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Codes
114
VOLUME 3, ESS Service Guide
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...