Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
40110000 Redundant power
supply failure.
See error code 40110001.
40110001
(E10/E20)
Cluster Bay Power
Failure.
This information is for Model (E10/E20). See the next table entry for the Model
(F10/F20) information.
1. Ensure the electronics cage power supplies (above the cluster bay) are
switched on.
2. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the working cluster bay and use the Repair
Menu, Show / Repair Problems Needing Repair option.
3. Check power cable connections to the P2 connector on the I/O Planar.
4. Replace I/O Planar.
5. Service processor card.
6. A card plugged into the I/O Planar that is drawing too much current can
cause this error. One or more cards can be removed to see if the failure
goes away. See
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
40110001
(F10/F20)
Cluster Bay Power
Failure.
This information is for Model (F10/F20). See the previous table entry for the
Model (E10/E20) information.
1. Ensure the electronics cage power supplies (above the cluster bay) are
switched on (at the rear of the power supply).
2. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the working cluster bay and use the Repair
Menu, Show / Repair Problems Needing Repair option.
3. Replace I/O Planar.
4. A card plugged into the I/O Planar that is drawing too much current can
cause this error. One or more cards can be removed to see if the failure
goes away. See MAP 4540: Cluster Minimum Configuration in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
40110002 Voltage not detected
on both CPU Cards.
1. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the working cluster bay and use the Repair
Menu, Show / Repair Problems Needing Repair option.
2. Check the power bus is connected to the top of each CPU card (E10/E20
only).
3. Ensure all cluster bay power cables are properly plugged into the power
distribution planar, system planar.
40110003 Voltage not detected
on one CPU card.
Use the service terminal to display problem needing repair and then replace the
failing CPU Card. Connect the service terminal to the working cluster bay and
use the Repair Menu, Display / Repair Problems Needing Repair option. If the
cluster bay is not active, display the SP Problem log on the failing cluster and fix
any related problems. See “Appendix A. Service Processor Operation
Connection” on page 209.
Replace the failing CPU card.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
89
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...