Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
20E00004 I/O Planar battery
drained or needs
replacement.
1. Replace I/O Planar battery.
2. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
20E00005 EEPROM locked.
1. The cluster bay needs to be power cycled. Connect the service terminal to
the working cluster and then use the Alternate Cluster Repair Menu options
to quiesce, power off, power on and resume the failing cluster.
2. If the problem is still present, replace the I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
20E00008 CMOS corrupted,
CMOS initialized.
1. If the I/O Planar battery is good (new), you can reset the NVRAM so it will
be reloaded on the next power up. To reset, remove the I/O Planar battery
and wait 15 minutes for the NVRAM to drain, or use a metal object to short
the metal contacts of the battery holder together which drains the NVRAM
immediately. Then install the battery and power up the cluster bay.
2. Replace the I/O planar battery to reset CMOS on the next power on.
3. Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
20E0000B EEPROM write
problem
Refer to actions for 20E00005.
20E0000C EEPROM read
problem.
Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
20EE0xxx Informational
See error code 20EE0003.
20EE0003 IP parameter requires
3 dots
″
.
″
Enter valid IP parameter.
Example: 000.000.000.000
20EE0004 Invalid IP parameter.
Enter valid (numeric) IP parameter.
Example: 000.000.000.000
20EE0005 Invalid IP parameter
(>255)
Enter valid (numeric) IP parameter in the range of 0 to 255.
Example: 255.192.002.000
20EE0006 No SCSI controllers
present
The I/O Planar should always have (at least) 2 integrated PCI SCSI controllers;
replace the I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
20EE0007 False keyboard not
found error.
Replace I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
20EE0008 No configurable
adapters found in the
system.
This warning occurs when the selected SMS function cannot locate any
devices/adapters supported by the function.
v
Replace I/O planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
v
Call the next level of support.
Codes
74
VOLUME 3, ESS Service Guide
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...