Table 13. Failing Function Code Table (continued)
Failing
Function
Code
FRU and Notes
221, 226,
227
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
241
Ethernet network problem
Note:
″
MAP 4390: Isolating a Cluster to Cluster Ethernet Problem
″
in chapter 3 of the Enterprise
Storage Server Service Guide, Volume 1
277
SCSI Signal Cable
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
292
CPU Card
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
293
PCI - PCI Bridge Problem
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
294
MPCI Interrupt Controller Problem
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
295
PCI - ISA Bridge Problem
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
296
PCI Device or Adapter Problem
The FRU can only be identified by it’s location code reported by diagnostics that gave this SRN and FFC.
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
2C4
System Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
2C6
128 MB DIMM
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
2C7
Base Memory Card
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
2C8
System Planar, I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
2C9, 2D2
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
2D3
Service Processor Card (2105 Model E10/E20 only)
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
Failing Function Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
133
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...