Attention: If this failure first occurred after replacing the I/O Planar (Model Exx/Fxx) or Service
Processor Card (Model Exx only), the firmware level may be incompatible. Call the next level of
support.
2. Call the next level of support for any of the following conditions:
v
A four-digit code in the range of E001 through EFFF displays on the operator panel but is not listed
in the checkpoint table.
v
A four-digit code displays in the checkpoint table, but does not contain a repair action or FRU
listing.
v
All of the FRUs listed in the repair action have been replaced and the problem has not been
corrected.
Table 10. SP Checkpoints.
Checkpoint
Description
Action/ Possible Failing FRU
E000
System Support Controller begins operation.
This is an informational checkpoint.
See note1 on page 100
E010
Starting SP self-tests
1. Service Processor (E10/E20 only)
2. I/O Planar(F10/F20 only, see notes on 72)
E011
SP self-tests completed successfully
None
E012
Begin to set up Service Processor helps
1. Service Processor (E10/E20 only)
2. I/O Planar(F10/F20 only, see notes on 72)
E01F
Bad self-test, cannot continue
Call next level of support
E020
Configuring CMOS
1. I/O Planar (See notes on 72 )
2. Service Processor (E10/E20 only)
E021
Configuring NVRAM
1. I/O Planar (See notes on 72 )
2. Service Processor (E10/E20 only)
E022
Accessing System Backplane VPD
System Planar
E023
Accessing Memory Card 1 VPD
Memory Card 1 (P1-M1)
E024
Accessing Memory Card 2 VPV
Memory Card 2 (P1-M2)
E025
Problem accessing VPD on memory card 1
I/O Planar(F10/F20 only, see notes on 72)
E026
Problem accessing VPD on memory card 2
I/O Planar(F10/F20 only, see notes on 72)
E02E
False
″
Hot Swap
″
fans and power supply
condition
1. I/O Planar (Call next level if it still fails )
E030
Beginning to build I2C resources
1. Service Processor (E10/E20 only)
2. CPU Card
3. I/O Planar (See notes on 72 )
E031
Finished building I2C resources
1. Service Processor (E10/E20 only)
2. CPU Card
3. I/O Planar (See notes on 72 )
E032
JTAG Self-Test
I/O Planar
E040
Starting serial port tests
1. Service Processor (E10/E20 only)
2. I/O Planar (See notes on 72 )
3. CPU Card
E042
Configuring serial port 1
1. Service Processor (E10/E20 only)
2. I/O Planar (See notes on 72 )
3. CPU Card
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
101
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...