Table 12. Service Request Numbers (continued)
Service
Request
Number
SRN
Src.
Failing
Function
Codes
Description and Action
101-558
A
Description: There is not enough memory to execute diagnostics.
Action: There must be a minimum of 16 MB of installed memory. The
memory card can be replaced now, or the minimum configuration map can
be used to remove some of the memory to isolate the problem. Go to
″
MAP
4540: Cluster Minimum Configuration
″
in chapter 3 of the Enterprise Storage
Server Service Guide, Volume 1.
101-559 to
101-599
A
Description: The cluster bay halted while software was loading. This
problem may be attributed to either hardware or software.
Action: Test the cluster bay. Boot from the SCSI Hard Drive (normal cluster
bay power on). Connect the service terminal, use Main Service Menu, then
Machine Test Menu, then cluster bay. If no problem is found, then go to
″
MAP 4020: SCSI Hard Drive Build
″
in chapter 3 of the Enterprise Storage
Server Service Guide, Volume 1.
101-711 to
101-726
A
Description: The cluster bay hung while trying to configure an unknown
resource.
Action: Test the cluster bay. Connect the service terminal, use Main Service
Menu, then Machine Test Menu, then cluster bay. If no problem is found,
then go to
″
MAP 4020: SCSI Hard Drive Build
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
101-727
A
212
Description: The cluster bay hung while trying to configure an
asynchronous adapter.
101–80C
A
7C1
Description: A potential problem with an SSA device exists. Use the service
terminal Repair Menu, Show / Repair Problem Needing Repair option for
any related problems.
101–840
A
169
Description: An unexpected system interrupt. Suspect the integrated SCSI
adapter on the I/O planar.
Action: Go to
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
101-888
A
227 E10
Description: The cluster bay does not IPL.
101-c33
D
Description: The cluster bay hung while indicating that a service terminal is
the system console.
Action: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1: Changing cluster
FRUs and do the procedure for replacing the I/O planar battery which will
reset the NVRAM values. You will need to remove the battery and ground
the battery socket contacts. You do not need to install a new battery unless
you suspect the battery has lost its charge.
101–c70
A
Description: The cluster bay hung while indicating that a service terminal is
the system console.
101-xxx
A
xxx 227
Description: A problem was encountered mounting the CD-ROM.
Action: Try another CD-ROM and then call the next level of support.
103-151
D
151
Description: The time-of-day battery on the I/O planar failed.
103-202 to
103-210
H
Description: Unexpected interrupt.
Action: Go to
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
115
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...