Table 12. Service Request Numbers (continued)
Service
Request
Number
SRN
Src.
Failing
Function
Codes
Description and Action
689-122
D
689
Description: A SCSI Hard Drive reservation conflict error.
689-124
D
689
Description: A SCSI check condition error occurred.
689-126
D
689 B88
Description: A software error was caused by a SCSI Hard Drive failure.
689-128
G
689
Description: The error log analysis indicates a SCSI Hard Drive failure.
689-129
G
D50 689 B88
software
Description: Problem log analysis indicates a SCSI bus problem.
689-130
G
689
Description: Problem log analysis indicates a problem reported by the
SCSI Hard Drive’s self monitoring function.
689-132
D
689
Description: A SCSI Hard Drive hardware error occurred.
689-134
D
B88 software
Description: The adapter failed to configure.
689-135
D
689 B88
software
Description: The SCSI Hard Drive failed to configure.
689-136
D
689
Description: The certify operation failed.
689-137
D
689 B88 D50
Description: Unit attention condition has occurred on the Send Diagnostic
command.
7C1-101
D
7C1 software
Description: Audio support failed (not used)
7C1-102
D
7C1
Description: CS4232 failed
7C1-103
D
7C1
Description: Clock control failed
7C1-107
D
7C1
Description: SoundBlaster support interface failed (not used)
7C1-108
D
7C1
Description: Loop back failed
7C1-109
D
7C1
Description: CODEC ID invalid
7C1-117
D
D97
Description: Internal speaker support failed (not used)
802-78C
C
Description: A system bus problem exists.
Action: System bus problem isolation
802-xxx
C
xxx
Description: The diagnostics did not detect an installed resource.
Note: To obtain the FFC substitute the last three digits of the SRN for xxx.
Display problems needing repair, there should be a related problem. If not,
call the next level of support.
803-xxx (See
note in Action
column.)
D
Use the xxx
number
Description: Diagnostics detected an error.
Action: Replace the FRU identified by the failing function code. If it still
fails, then go to
″
MAP 4540: Cluster Minimum Configuration
″
in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
804-111
D
804 B88
Description: Unable to reserve device.
804-112
D
804 B88
Description: Unable to do configuration.
804-113
D
804 B88
Description: Unable to open the device driver.
804-121
D
804
Description: The CD-ROM drive indicates an error.
804-122
D
804
Description: The CD-ROM drive indicates an error.
804-123
D
804
Description: The CD-ROM drive indicates an error.
804-125
D
804 B88
Description: The CD-ROM drive indicates an error.
804-126
D
804
Description: The CD-ROM drive indicates an error.
804-127
D
804
Description: The CD-ROM drive indicates an error.
Codes
122
VOLUME 3, ESS Service Guide
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...