Description of the Failing Function Code Table
The failing function codes are listed in numerical sequence.
The columns in the failing function code table are as follows:
Failing Function Code, The failing function code number from the SRN.
FRU and Notes, This column contains the description of the FRU and any usage notes.
Failing Function Code Table
Lookup the Failing Function Code in the following table to determine the FRU.
For all cluster FRU replacement, go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Table 13. Failing Function Code Table
Failing
Function
Code
FRU and Notes
131
Unidentified memory error. Check all Memory Modules to be present and properly installed. Check all
Memory Modules to be the same. If no discrepancy is found then replace the memory module in the
location called out by the blinking 888 cluster operator panel codes, reference go to
″
MAP 4240: 888
Blinking on Cluster
″
in chapter 3 of the Enterprise Storage Server Service Guide, Volume 1.
If the memory error is still present, go to
″
MAP 4240: 888 Blinking on Cluster
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
151
I/O Planar Battery
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
152
Electronics cage power system problem detected by the cluster bay.
Note:
″
MAP 2540: Power Problem Detected by Cluster Bay
″
in chapter 3 of the Enterprise Storage
Server Service Guide, Volume 1
165
Cluster Operator Panel, Cluster Operator Panel Cable
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
169
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
181
Diskette Drive Signal Cable
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
190
SCSI Signal Cable
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
210
CPU Card
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
212
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
214 & 217
CPU Card
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
Failing Function Codes
132
VOLUME 3, ESS Service Guide
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...