Table 12. Service Request Numbers (continued)
Service
Request
Number
SRN
Src.
Failing
Function
Codes
Description and Action
651-821
G
2E1
Description: Cluster Bay shutdown due to an over maximum temperature
condition being reached.
Action: See SRN, 651-152
651-831
G
152 2E2
Description: Sensor detected a voltage outside of the normal range.
651-832
G
2E1
Description: Sensor detected an abnormally high internal temperature.
Action: See SRN, 651-152
651-839
G
Description: Sensor detected a FRU that has failed.
Action: Use the physical location code(s) to replace the FRU(s) that are
identified on the problem detail screen.
651-841
G
152 2E2
Description: Sensor detected a voltage outside of the normal range.
651-842
G
2E1
Description: Sensor detected an abnormally high internal temperature.
Action: See SRN, 651-152
651-843
G
152 E19
Description: Sensor detected a power supply failure.
651-849
G
Description: Sensor detected a FRU that has failed.
Action: Use the physical location code(s) to replace the FRU(s) that are
identified on the problem detail screen.
652-600
G
Description: A non-critical error has been detected and corrected:
Uncorrectable memory or unsupported memory.
Action: Examine the memory modules and determine if they are supported
types. If the modules are supported, then replace the appropriate memory
module(s).
652-610
G
210
Description: A non-critical error has been detected and corrected: CPU
internal error.
652-611
G
210
Description: A non-critical error has been detected and corrected: CPU
internal cache error.
652-612
G
D01
Description: A non-critical error has been detected and corrected: L2 cache
parity or multi-bit ECC error.
652-613
G
D01
Description: A non-critical error has been detected and corrected: L2 cache
ECC single-bit error.
652-623
G
2C6
Description: A non-critical error has been detected and corrected:
Correctable error threshold exceeded.
652-731
G
2C8 292
Description: A non-critical error has been detected and corrected:
Intermediate or Cluster Bay Bus Address Parity Error.
652-732
G
2C8 292
Description: A non-critical error has been detected and corrected:
Intermediate or Cluster Bay Bus Data Parity Error.
652-733
G
214 2C8 292
Description: A non-critical error has been detected and corrected:
Intermediate or Cluster Bay Bus Address Parity Error.
652-734
G
214 2C8 292
Description: A non-critical error has been detected and corrected:
Intermediate or Cluster Bay Bus Data Parity Error.
652-735
G
2D2 292
Description: A non-critical error has been detected and corrected:
Intermediate or Cluster Bay Bus Time-out Error.
Codes
120
VOLUME 3, ESS Service Guide
Содержание E10
Страница 2: ......
Страница 68: ...52 VOLUME 3 ESS Service Guide...
Страница 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Страница 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Страница 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Страница 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Страница 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Страница 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Страница 277: ......
Страница 278: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SY27 7609 06...
Страница 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...