a.
Log into IBM Storage Configuration Manager.
b.
Select
BCS SAS RAID Module
>
Health
>
All Resources
.
c.
Verify that the status is
Normal (Online)
.
11.
If the problem is not resolved, collect the logs and contact IBM.
Replacing 6-Disk storage module with 12-Disk Storage Module
from Command Line Interface (CLI)
About this task
6-Disk Storage Module (DSM) is the enclosure holding up to six disk drives while
12-Disk Storage Module holding up to 12 disk drives. 12-DSM is supported in the
BladeCenter S chassis only with a minimum SAS RAID Controller(RSSM)
Firmware code level 1.3.0.008. Both controllers are required to update the FW
newer than version 1.3.0.008 before 12-DSM installation. Perform the following
steps to non-concurrently replace the 6-DSM with 12-DSM installation.
Procedure
1.
Log in to the RAID Controller Command Line Interface(CLI).
2.
Confirm both controllers are in a minimum FW code level of 1.3.0.008. Update
the SAS RAID controller firmware to code level higher than or equal to version
1.3.0.008. The firmware update procedure please refer to
IBM SAS RAID
Controller Module Installation and User's Guide in
firmware,” on page 33
At the <CLI> prompt, enter
swversion
and press Enter to list the controllers
firmware version. The Package Build No should be no older than 1.3.0.008.
<CLI> swversion
Current Machine Local Time: 03/04/2013
04:57:44 PM
Software version
: 3.0.0.6
UBoot version
: H-1.1.4.6
OS
version
: H-2.4.20.12
SES version
: 0107
BMC version
: S0BT10A
0121 02/08/2010
FPGA version
: 01.07
CPLD version
: S0CP00A
C00A 01/01/2000
SAS switch version
: S0SW01D
R107 12/17/2009
BBU FirmwareRev
: 58.0
Package Build No
: 1.3.0.008
3.
At IBM SAS RAID controller Command Line Interface(CLI) prompt, enter
shutdown -system -state servicemode
and press Enter to prepare the controller
for service. The controller that is prepared for service will reboot in the
SERVICE state.
<CLI> list controller
Current Machine Local Time: 03/04/2013
04:37:02 PM
_______________________________________________________________________
|
Ctlr#
|
Controller
|
Status
|
Ports
|
LUNs
|
|_____________|________________|____________________|_________|_________|
|
0 |
Ctlr0|
PRIMARY|
1|
0|
|
1 |
Ctlr1|
SECONDARY|
1|
0|
|_____________|________________|____________________|_________|_________|
<CLI> shutdown -system -state servicemode
Current Machine Local Time: 03/04/2013
04:37:16 PM
Shutdown Command Successful
158
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...