configure alert
The
configure alert
command selects the alert messages to send by email.
Previously configured messages display as
configured
and can be cleared.
Use the
-get
option to display the list of alerts and to build a local list of system
alerts before using the
–set
option to configure the alerts. Use the
-set
option to
clear the list. An error appears if you issue the
–set
option while the list is empty.
Command arguments:
<CLI> configure alert [ -get | -set | -setgenericalerttemplate ]
-help option
Usage
: configure alert -[get | set [-email | -initiallymasked]
-on <RefNum RefNum...> -off <RefNum RefNum...>
| setgenericalerttemplate -code <genericAlertCode>
-type [persistent|ackable] -initiallymasked [on|off]
-email [on|off] -severity [critical|warning|info]
-msg "DesiredAlertStringInQuotes"]
[-get]
: Displays the email and initiallymasked properties of alerts
currently defined in alertTemplates.
[-set]
: Enables the user to set the email and initiallymasked attribute
for any email.
[-setgenericalerttemplate] : Enables the user to create or replace an entry in alertTemplates
for generic alerts.
on
: Sets the attribute to ’on’ for the alertCode specified by RefNum.
off
: Sets the attribute to ’off’ for the alertCode specified by RefNum.
: When email attribute is set for an alert, an email is generated
every time that alert is created in the system.When this attribute
is set, email is only generated for future events and not for
existing alerts.
initiallymasked
: When this attribute is set for an alert, initiallymasked LED is
lighted every time that alert is created in the system.When this
attribute is set, LED is lighted for future events and not for
existing alerts.
type
: Defines the type of alert for generic alert being specified.
severity
: Defines the severity of alert for generic alert being specified.
msg
: Defines the message for the generic alert. The string should be
specified within quotes for this command. The string is saved in
the alertTemplates without the quotes.
Where:
v
number
- Defines the reference number of the alert displayed by using the
-get
option.
Examples:
<CLI> configure alert -get
Current Machine Local Time: 04/08/2009
09:47:11 AM
Ref# Code
EmailOn
InitialMask
AlertMsg
State
State
---- ----- -------
-----------
--------
1
0
On
Unmasked
TestAlert %s
2
2
Off
Masked
Compatible drive enclosure %<EnclosureId> found
3
3
Off
Masked
Drive enclosure %<EnclosureId> removed
4
4
Off
Masked
Drive enclosure %<EnclosureId> firmware updated
5
100
On
Masked
Controller firmware updated
6
101
Off
Masked
Disorderly shutdown detected - System restored from battery
backup
7
102
On
Unmasked
Controller in survivor mode - Redundant controller
%<ControllerId> is offline
8
103
Off
Masked
New controller recognized
9
104
Off
Masked
Replacement media tray %<BackplaneId> detected
Chapter 8. Using the RAID Controller command line interface
63
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...