2100
Controller ready for service
controller_ID
Explanation:
A previously bound controller is ready for removal. Possible causes:
v
Unrecoverable controller failure.
v
Operator requested offline condition (part of the concurrent controller replacement procedure).
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. The controller fault light turns on, indicating "ready to remove" state. Alert clears if
controller is rebooted.
Operator response:
Replace the controller.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator. Masking the
alert does not prevent the controller fault light from illuminating.
2101
Controller ready for service. RAID System is down due to
service_mode_reason
Explanation:
The controller was in Survivor/Standalone state and has entered offline state due to a unrecoverable
error or by operator request. The controller is now ready for service. This alert is triggered by any of the following
events:
v
SES not accessible
v
BMC not accessible
v
VPD not accessible
v
Battery backup is low or has failed
v
SES is reporting critical environmental
v
User requested service mode case
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. The controller fault light turns on, indicating "ready to remove" state.
v
If battery backup was low, the alert clears when charge returns to sufficient.
v
If SES reported critical environmental, the alert clears when SES environmentals return to normal.
v
For other problems, the alert clears after the problem is corrected and the controller is rebooted.
Operator response:
Correct the problem. Reboot the controller. If the problem persists, replace the controller.
2200
Battery
battery_ID
ready for service
Explanation:
The battery is detected present by SES, but has failed or expired. It is ready to be removed.
System action:
Battery fault light turns on, indicating "ready to remove" state. By default, the SAS RAID Module
system information indicator is turned on and the operator is notified of this alert by e-mail. Alert clears when the
battery is removed.
Operator response:
Replace the battery (see “Replacing a Battery Backup Unit” on page 177).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
2100 • 2200
130
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...