4322
Drive carrier
tray_ID
contains one or more unreliable or unsupported drives and cannot be mounted.
Please remove drive(s)
drive_list
and reinsert.
Explanation:
Cannot mount tray due to unreliable or unsupported drives
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the tray is removed.
Operator response:
Remove unsupported or unreliable drives from system.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5300
Drive
drive_ID
firmware update failed
Explanation:
Attempted drive firmware update operation was unsuccessful.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately. Retry the firmware update.
5301
Surplus capacity of replacement drive
drive_ID
will not be utilized
Explanation:
Drive in replacement tray has too much capacity.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Replacement drive detection treats this as a qualified replacement drive and
automatically uses the spare. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
5302
Drive
drive_ID
cannot be used as a replacement.
Explanation:
Replacement drive is not qualified. This alert indicates that replacement drive detection has been
disabled for this group.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately. Assign a replacement spare drive manually.
5303
No drives discovered
Explanation:
No drives were discovered during system boot-up. RAID Zero Step Setup is disabled.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears automatically when at least one drive is discovered.
Operator response:
Acknowledge to clear the alert immediately.
4322 • 5303
136
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......