4301
Unmasked drive firmware level is unsupported
Explanation:
A disk drive with an unsupported firmware level is detected by the controller.
System action:
The controller will not configure the disk drive.
Operator response:
Remove the disk drive with the unsupported firmware level, or upgrade the disk drive
firmware level.
4302
Drive
drive_ID
specifies one or more missing drives already determined to be missing from a
previously discovered drive group. This drive is a member of drive group
group_ID
, a RAID
raid_level
group containing drive(s)
drive_list
.
Explanation:
A drive group has been discovered that specifies one or more member drives that are missing from the
system and already described as members of a previously discovered drive group. The previously discovered drive
group need not be mounted to cause this alert.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drives are assimilated or removed from the system.
Operator response:
Assimilate or remove the affected drives.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
4303
Drive
drive_ID
specifies a group whose identity conflicts with an existing group. This drive is a
member of drive group
group_ID
, a RAID
raid_level
group containing drive(s)
drive_list
.
Explanation:
A drive group is discovered whose GUID conflicts with an already recreated group. The previously
discovered group need not be mounted to cause this alert.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drives are assimilated or removed from the system.
Operator response:
Assimilate or remove the affected drives.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
4304
Drive
drive_ID
cannot be mounted without exceeding controller resource limits. This drive is a
member of drive group
group_ID
, a RAID
raid_level
group containg drive(s)
drive_list
.
Explanation:
A drive group is discovered that, if mounted, would cause one or more controller resource limits to be
exceeded (max volumes, max hosts, max terabytes, etc.).
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears when the affected drives are assimilated or removed from the system.
Operator response:
Assimilate or remove the affected drives.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
4301 • 4304
Chapter 11. Troubleshooting and support
135
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...