0325
Drive carrier
tray_ID
removed
Explanation:
A drive carrier tray that was previously known to exist was detected as missing by SES.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0326
Drive carrier
tray_ID
inserted
Explanation:
Detected new tray via SES.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0328
Tray spare drive
drive_ID
discovered in drive carrier
tray_ID
with one or more assigned drives -
Drive converted to global spare
Explanation:
Drive in tray is tray spare drive, but tray is not a spare tray.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0330
Drive
drive_ID
containing stale metadata has been discovered after initial system boot. This drive is
a member of drive group
group_ID
, a RAID
raid_level
group containing drive(s)
drive_list
.
Explanation:
The controller allows missing member drives of groups discovered at boot up and spare drives to be
hot plugged into the system after initial boot up. However, if a hot plugged drive's metadata indicates that the drive
is part of a drive group that was not discovered during system boot up, no group is listed, the drive is reported as
assigned, and this alert is generated. The arguments in this alert indicate the group to which the drive belongs. To
mount the drive as is, a controller restart is required. The alert persists until acknowledged by the user or the drive is
removed.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears when the drive is assimilated or removed.
Operator response:
Acknowledge to clear the alert immediately. Assimilate or remove the drive.
1300
Drive
drive_ID
failure detected- Previous drive status was
[
inuse
|
spare
]
Explanation:
Drive failure condition caused controller to fail a drive group member or spare drive.
System action:
Drive mount state is set to DISMOUNTED. By default, the SAS RAID Module system information
indicator is turned on and the operator is notified of this alert by e-mail. This alert (and all other 13xx alerts) is
cleared when the drive is removed.
Operator response:
Replace the failed drive (see “Replacing a failed drive” on page 167).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
0325 • 1300
132
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...