5405
Drive group
group_ID
has been degraded due to enclosure
enclosure_ID
fault condition. Drive(s)
drive_list
removed from drive group.
Explanation:
Forced orderly dismount due to enclosure critical environmentals caused one or more "dropped"
drives, but the group is still viable.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately.
5406
Long-running task canceled prior to completion:
task_info
Explanation:
Volume service permanently aborted.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
5410
Stale drive group conflicting group name
group_ID1
has been renamed to group name
group_ID2
Explanation:
Group rename occurred during discovery.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
5413
Previously mounted drive group
group_ID
comprised of drives
drive_list
does not match current
controller ID and has been removed from mounted group list.
Explanation:
MGL group found but does not match the ID of this controller on cold boot.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately.
5414
Drive group
group_ID
is offline due to one or more missing drives.
Explanation:
This alert is generated when a group becomes non-viable due to one or more missing drives. This can
occur at system startup if the group cannot be mounted due to missing non-redundant drives, or during normal
operation if the group was previously mounted and connectivity to one or more non-redundant drives is lost.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately. Reinsert the missing drives.
Note:
In the R1 release, you must reboot the system with the missing drives in place in order to return the group
and its associated volumes to the mounted viable state with mapped LUNs online and accessible.
5405 • 5414
142
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...