e.
Click
Restore Defaults
.
f.
Click
OK
.
g.
Click OK.
11.
Power on the SAS RAID Module in Bay 4.
a.
Click
I/O Module Tasks
>
Admin/Power/Restart
.
b.
Select the check box next to
Bay 4
.
c.
Select
Power On Module(s)
.
d.
Click
OK
.
12.
Verify that both SAS RAID Modules powered on. The word
On
is displayed
in the
Pwr
column for both SAS RAID Modules.
What to do next
If this process does not resolve the problem, collect the logs and contact IBM.
Concurrent repair procedures
Concurrent repair procedures can be performed even if application I/O processes
are running. This section contains the concurrent repair procedures for the IBM
BladeCenter S SAS RAID Controller Module.
Note:
Before you perform a concurrent repair procedure, make sure the firmware
level of your RAID controllers is 1.2.2.007 or newer.
Replacing a single controller in a dual controller configuration
using the CLI
Perform the following steps to concurrently replace a single RAID Controller in a
dual controller configuration using the RAID Controller command line interface
(CLI).
Procedure
1.
Log into the chassis using the Advanced Management Module and illuminate
the blue chassis identification LED to ensure the repair action is conducted on
the correct chassis.
a.
Log into the Advanced Management Module.
b.
Click
Monitors
>
LEDs
>
Media Tray and Rear Panel LEDs
.
c.
Click
On
or
Blink
next to
Location
. Depending on the selection, the blue
chassis identification LED will be in the SOLID or BLINKING state.
2.
Remove any externally attached devices that are connected to any of the four
SAS ports on the RAID Controller that is being replaced.
3.
Log into the CLI of the RAID Controller.
4.
At the
<CLI>
prompt, enter
list controller
and press Enter to verify the
controllers are operating in a dual primary-secondary state.
<CLI> list controller
_______________________________________________________________________
|
Ctlr#
|
Controller
|
Status
|
Ports
|
LUNs
|
|_____________|________________|____________________|_________|_________|
|
0 |
Ctlr0|
PRIMARY|
1|
0|
|
1 |
Ctlr1|
SECONDARY|
1|
0|
|_____________|________________|____________________|_________|_________|
5.
At the
<CLI>
prompt, enter
shutdown –ctlr <CONTROLLER 0 OR 1> –state
servicemode –readytoremove
and press Enter to prepare the controller for
164
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...