9304
One or more outstanding alert 9302 conditions exist. Acknowledge to proceed with shutdown.
Explanation:
System shutdown initiated with outstanding 9302 alerts.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when all 9302 alerts are cleared. Alert clears automatically after 120
seconds.
Operator response:
Acknowledge to clear the alert immediately. Restore the missing drive.
9308
Drive
drive_ID
contains metadata protocol violation. Drive state set to incompatible metadata.
Explanation:
Read errors existed in both metadata copies during drive discovery.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when the drive is removed or assimilated.
Operator response:
Remove or assimilate the drive.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
9310
Drive
drive_ID
not accessible during power fail recovery, please restore connectivity or acknowledge
to skip power fail recovery for drive group
group_ID
with potential indeterminate data loss.
Explanation:
A non-redundant drive was missing during power failure recovery. Auto Ack Pending Non-Viable is
disabled.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. The alert clears when the missing drive is inserted or the drive group becomes viable.
After a predefined delay, the controller initiates RAID Zero Step Setup configuration.
Operator response:
Acknowledge to clear the alert immediately. Insert the missing drive (or enough drives to make
the drive group viable).
Note:
Because you might want to add more than the minimum number of drives, the controller does not initiate
Zero Step Setup configuration immediately after discovering a sufficient number of drives. Instead, the controller
waits for predefined period (the default is 60 seconds) after each drive insertion so that you have time to add more
drives. If that period elapses without further drive insertions, Zero Step Setup configuration begins.
Drive group alerts
The alerts in this section are generated to inform the operator of changes in drive
group status.
0400
Long-running task started:
task_info
Explanation:
Volume service started.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds. Alert clears immediately when
volume service is suspended or cancelled.
Operator response:
Acknowledge to clear the alert immediately.
9304 • 0400
Chapter 11. Troubleshooting and support
139
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...