9600
Controller unable to bind - Usable drives different than survivor controller
Explanation:
Unable to rebind with survivor due to missing drives that survivor can see or more drives than the
survivor sees. Possible causes include drive or expander failures.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the controller reboots and all drives are discovered properly.
Operator response:
Repair drive connectivity.
9601
Controller reports RAID system unable to begin operations - Usable drives different in each
controller
Explanation:
Two controllers booting up see different drives, and neither controller can see all of the same drives as
the other controller. Possible causes include drive or expander failures.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when controller reboots and all drives are discovered properly.
Operator response:
Repair drive connectivity.
Controller configuration alerts
The alerts in this section are generated to inform the operator of problems related
to controller configuration.
0700
Controller
controller_ID
configuration script
script_name
execution complete
Explanation:
System configuration script has completed with no errors.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0701
Controller port
port_ID
IP address changed to
IP_address
Explanation:
Requested IP address applied.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately.
0702
Controller timestamp updated
Explanation:
Other controller and backplane timestamps are in sync, but the timestamp for this controller does not
match.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears automatically.
Operator response:
None.
9600 • 0702
148
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...