9511
Volume
volume_ID
data redundancy error encountered - Bad blocks created in LBA range
LBA1
to
LBA2
Explanation:
Redundancy scan found and corrected incoherency, but created bad blocks.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately. Rewrite affected volume LBAs if possible.
9512
Volume
volume_ID
migrate incomplete and source group is missing. Volume has been deleted.
Explanation:
Volume migrate was suspended or interrupted, and source group is not available at system reboot
time.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail.
Operator response:
Acknowledge to clear the alert immediately.
Host and connectivity alerts
The alerts in this section are generated to inform the operator of changes in host or
connection status.
4601
Controller host port connectivity error
Explanation:
Controller detected an unexpected loss of connectivity on an enabled host port.
v
For a FibreChannel host port, this alert is generated when a link down condition is detected on the host port.
v
For a SAS host port, this alert is generated when a 106x internal fault condition requires a 106x reset.
v
This alert is not generated for an Apache host port.
System action:
By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. Alert clears when the host port connectivity is restored.
Operator response:
Replace the controller or host switch.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5600
Illegal host
host_ID
access attempted
Explanation:
An invalid SCSI initiator port (host) has attempted to access the system.
v
For a FibreChannel host port, this alert is generated when a PLOGI frame is received from a host that does not
have any LUNs mapped to it.
v
For all other types of host ports, this alert is generated when a SCSI command is received from a SCSI initiator
port (host) that does not have any LUNs mapped to it.
System action:
By default, the SAS RAID Module system information indicator is not turned on and the operator is
not notified of this alert by e-mail. Alert clears when the host becomes valid by being added to the system. Alert
clears automatically after 120 seconds.
Operator response:
Acknowledge to clear the alert immediately. Add host and map LUN to allow access.
9511 • 5600
Chapter 11. Troubleshooting and support
147
Содержание BladeCenter S SAS RAID Controller Module
Страница 2: ......
Страница 7: ...Taiwan Class A compliance statement 199 Index 201 Contents v...
Страница 10: ...viii IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 40: ...30 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 101: ...host get Chapter 8 Using the RAID Controller command line interface 91...
Страница 102: ...92 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 104: ...94 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 196: ...186 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 200: ...190 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 209: ...Taiwan Class A compliance statement Notices 199...
Страница 210: ...200 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 214: ...204 IBM SAS RAID Controller Module Installation and User s Guide IBM BladeCenter S SAS RAID Controller Module...
Страница 215: ......
Страница 216: ...Part Number 00D9332 Printed in USA 1P P N 00D9332...