![HP HP 8566B Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/hp/hp-8566b/hp-8566b_adjustment-manual_161563064.webp)
10. Frequency Response Test
Figure 2-19.
Frequency Response
Setup (60 MHz to 2.5
2 to 22
36. Connect equipment as shown in Figure 2-19, with one resistive
output of the power splitter connected to the power meter/power
sensor, and the second resistive output connected to the spectrum
analyzer RF INPUT using an APC 3.5 (m) to Type N (m) adapter.
Connect the power meter rear panel RECORDER OUTPUT to the
synthesized sweeper front panel LEVELING EXT INPUT.
37. On the power meter, verify that the
[
RANGE HOLD
)
switch is off.
Consult the power sensor Cal Factor versus Frequency graph or
table and set the power meter CAL FACTOR switch to the 100
MHz calibration setting.
38. Press
PRESET
]
on the synthesized sweeper. Set the controls
of the synthesized sweeper as follows:
CW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 MHz
POWER LEVEL . . . . . . . . . . . . . . . . . . . . . -9.0
RF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . on
LEVELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . INT
39. On the synthesized sweeper, press
(
POWER
and adjust the
ENTRY knob for a power meter indication of -15.00
fO.10
at 100 MHz.
40. On the power meter, press
(
RANGE HOLD
)
(turning it on).
41.
On
the synthesized sweeper, press
[
POWER LEVEL
)
and adjust the
ENTRY knob for a power meter indication of -10.00
at
100 MHz.
42. On the synthesized sweeper, press
leveling and adjust the
ENTRY knob (REF in
with ATN: 0
for a power meter
indication of -10.00
at 100 MHz.
Do not vary the synthesized sweeper POWER LEVEL setting (internal
leveling) or METER REF and METER ATN settings (external power
meter leveling) for the remaining steps in this test procedure.
Performance Tests 2-39
Содержание HP 8566B
Страница 71: ......
Страница 137: ...Test 19 1st LO Output Amplitude Steps Min Measured Max 4 1st LO OUTPUT Level 5 dBm 2 112 Performance Tests ...
Страница 169: ......
Страница 344: ......
Страница 351: ...23 Track and Hold Adjustments 25 Repeat steps 4 through 24 until no further adjustments are required Adjustments 3 211 ...
Страница 404: ...AIVI Wi AlAl ti2 W8 Figure 6 6 IF Section Front View 6 8 Major Assembly and Component locations ...